{"product_id":"greenconnect-wireless-modbus-gateway-lora-to-modbus-tcp-ip67","title":"GreenConnect Wireless Modbus Gateway - LoRa to Modbus TCP, IP67","description":"\u003cp dir=\"ltr\"\u003eThe GreenConnect Wireless Modbus Gateway connects remote Modbus RTU devices to a building network over a long-range LoRa radio link. It receives Modbus RTU traffic from GreenConnect Wireless Modbus Nodes and converts it to Modbus TCP, so a BMS, PLC, or SCADA system on the LAN can poll field devices by IP address.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe unit ships assembled and bench-tested in a sealed IP67 enclosure. Connect the RJ45 Ethernet port to the building network, plug the unit into a 120 V outlet, and assign it an IP address. One Gateway can serve multiple Nodes on the same channel, provided every Modbus device on the network has a unique slave ID.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat’s included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eComponent\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoRa radio\u003c\/td\u003e\n\u003ctd\u003eIndustrial LoRa radio, Semtech SX1262 chipset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAntenna\u003c\/td\u003e\n\u003ctd\u003eExternal antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol converter\u003c\/td\u003e\n\u003ctd\u003eModbus RTU to Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork port\u003c\/td\u003e\n\u003ctd\u003eRJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eInternal, powers radio and converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge suppressor\u003c\/td\u003e\n\u003ctd\u003eProtects internal electronics from line surges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cord\u003c\/td\u003e\n\u003ctd\u003e120 VAC plug, 3 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork protocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, port 502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField protocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003eRJ45, [10\/100 Mbps]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP addressing\u003c\/td\u003e\n\u003ctd\u003e[Static or DHCP]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimultaneous TCP connections\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless\u003c\/td\u003e\n\u003ctd\u003eLoRa, 902–928 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eUp to 5 km line of sight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput power\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67, 200 x 120 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cord\u003c\/td\u003e\n\u003ctd\u003e3 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eBringing wireless Modbus RTU devices onto a BMS or SCADA network as Modbus TCP\u003c\/li\u003e\n\u003cli\u003eWireless submetering with meters read over the building LAN\u003c\/li\u003e\n\u003cli\u003eConnecting rooftop, cellar, or remote-building equipment to a central controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Requires at least one GreenConnect Wireless Modbus Node at the equipment end. Range depends on building construction and antenna placement. Radio round-trip time is longer than a wired connection; set the Modbus TCP response timeout in your BMS to at least 2 seconds.\u003c\/p\u003e","brand":"Green Apple Lighting","offers":[{"title":"Default Title","offer_id":49857284178075,"sku":null,"price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0524\/8984\/6939\/files\/GreenConnectWirelessModbusGatewayDatasheet.png?v=1792438499","url":"https:\/\/greenappleenergycompany.com\/products\/greenconnect-wireless-modbus-gateway-lora-to-modbus-tcp-ip67","provider":"Green Apple Lighting","version":"1.0","type":"link"}