Local Law 88 Sub-Metering Solution. Measures voltage, frequency, current, power, active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVArh.  Can be used for single phase, 3 phase 3 wire or 3phase 4 wire systems;

Can be used for Local Law 88 Tenant Sub-metering.  Customers can also subscribe to our  GreenConnect cloud system to take advantage of plug-and play communication and monthly invoicing or tenant reporting.  

Connectivity 

  • Modbus RTU

Enclosure Specs (1 included)

  • Hinged cover with slotted-head quarter-turn cam lock.
  • Heavy duty 16 gauge welded steel construction.
  • Easily removable concentric knockouts on all four sides for industry standard conduit sizes.
  • Four wall mounting holes in back.
  • Embossed grounding hole in bottom allows easy access and flush wall mounting. Durable ANSI 65 grey powder coating.
  • Complies with NEMA and UL type 1 rating.

3-pole Circuit Breaker included

  • Rated Voltage: 500 Volt; Rated Current: 1 Amp.
  • Total Size: 10x38mm/0.4x1.5" (D*L).
  • Fuse Type: Quick Breaking.
  • Quick acting design protects crucial electrical system components and wiring.
  • Mainly used for protecting the electrical circuit against overload and short circuit, it also derive for protecting the semiconductor objects.

Electric Meter Specs (1 included)

CT Options Specs (3 included)

Electric Input Characteristics:

  • Phase to phase 85 to 275V a.c. 50/60Hz ±10%
  • Phase to phase 120V to 380V d.c. ±20%.
  • Consumption < 25W.
  • Monitoring 480VAC Requires the use of a stepdown transformer to 120VAC


Applications:

  • Local Law 88 Reporting (NYC)
  • Utility submetering (electric, gas, water, etc.).
  • Metering in existing buildings (retrofit)
  • Cost Allocation.
  • Measurement and Verification.
  • Benchmark building energy usage.
  • Multi-tenant submetering projects
  • Environmental monitoring.
  • Track energy use and peak demand for Demand Response.
  • DC current monitoring for Renewable Energy.

Clarifications and Exclusions:

  1. Installation and setting up cost are not included, but can be offered to an additional cost.
  2. GreenConnect integration also available to an additional cost. Monthly support and maintenance fees comes with this service.
  3. Customized options available.